Avenyx Bio

A clearer view
of what we know.

The current foundation is laboratory-scale evidence. Explore each finding and the question it helps address.

Explore the signal.
Understand the structure.

Rotating triple-helix schematic

Move your pointer across the structure to change the viewing angle.

The positive band

Explore the original CD spectrum alongside a schematic of collagen’s three chains.

222 nm
190 nm260 nm

Selected position · 222 nm

Open the original figure ↗

The plots are the supplied laboratory figures. The moving structure explains the concepts; it does not reproduce measured molecular motion. Raw spectral exports are not available in this viewer, so it does not calculate intensities, helix percentages or a melting temperature. Background on collagen spectroscopy ↗

01 FTIR + circular dichroism Structure

Avenyx reports FTIR and CD findings supporting retained triple-helix characteristics in isolated collagen. These are structural signals from lab-scale characterization.

02 Type I collagen Identity & function

Type I collagen has been isolated, with receptor binding reported as validated. Performance in a specific formulation or application requires its own evaluation.

03 ~35% yield In-house result

Reported yield from in-house laboratory work. Commercial throughput and manufacturing economics require validation as the process scales.

04 ~45°C Onset of spectral weakening

The thermal CD heatmap shows the positive band near 220 nm persisting into the mid-40s Celsius and weakening in the higher-temperature rows. Approximately 45°C is a visual estimate of where weakening begins, based on measurements at 5°C intervals. A fitted melting temperature has not been reported.

Look at
the measurements.

Selected figures from Avenyx’s laboratory evidence materials. Open a study for its image, reported method and interpretation.

01 FTIR spectrum Structural characterization
Original sample spectrum labelled “Collagen 1”. Wavenumber in cm⁻¹; vertical axis is transmittance.

The reported finding

The supplied analysis compares amide-region features with a literature reference and reports structural similarity to collagen. This plot is a sample spectrum; the literature figure is not shown as Avenyx data.

Source: Avenyx evidence materials, FTIR analysis.

02 Circular dichroism Temperature-dependent spectra
Original CD and HT plots. The supplied figure does not identify the temperature corresponding to each coloured trace.

Reported acquisition settings

Transcribed from the CD methods block
InstrumentJasco J-1500
SampleCollagen I, 0.75 mg/mL
Wavelength range190–260 nm
Temperature ramp4–54°C
Interval5°C
Measurement solvent0.5% acetic acid, confirmed by instrument report
Scanning speed100 nm/min

The source reports gradual spectral change with temperature. The temperature-resolved heatmap below provides the context for the approximate 45°C spectral-weakening threshold.

Method clarification

The instrument report confirms 0.5% acetic acid as the measurement solvent. The earlier presentation separately mentions 5% for redissolution; that preparation detail is not resolved by this report. The overlaid spectra above have no colour-to-temperature legend. The thermal report below supplies a temperature axis. Its heatmap supports a visual estimate of spectral weakening above approximately 45°C; a fitted transition temperature has not been reported.

03 Receptor binding Supernatant depletion assay
Labelled assay panel, preserving the source’s lane and protein annotations.

The assay described

The receptor and control proteins were incubated with Type I atelocollagen under native conditions. Centrifugation separated bound and unbound fractions, and the supernatant was analysed by SDS-PAGE.

The source interprets receptor depletion in the supernatant, alongside the control proteins, as evidence of binding.

Source: Avenyx evidence materials, collagen binding assay.

04 Comparative gel Size-based comparison
The displayed comparison uses the five labelled lanes selected in the source document.

The comparison shown

The supplied panel compares migration patterns across rat-tail, marine and chicken-feet Type I samples.

It provides a size-based comparison to accompany the spectroscopy and binding evidence. The image is presented without deriving a purity percentage or assigning additional band identities.

Source: Avenyx evidence materials, comparative analysis.

05 Thermal CD map Instrument report
Original instrument figure. The heatmap spans the temperature series; the two line plots below it are labelled 3.94°C.

Confirmed measurement context

Instrument metadata · 15 May 2026
Measurement solvent0.5% acetic acid
Sample label0.75 mg/mL collagen
Temperature programme4–54°C, 5°C intervals
Ramp setting10°C/min; Halt mode
Acquisition range260–190 nm
Data pitch0.1 nm · 701 points
Bandwidth / D.I.T.1 nm / 4 seconds
Baseline correctionNone, as recorded
Accumulations1

The positive CD band near 220 nm remains prominent into the mid-40s Celsius, then weakens toward the top of the heatmap. This supports an approximate onset of spectral weakening above 45°C.

Visual interpretation · 5°C temperature steps. The approximate threshold is not a fitted melting temperature or a guaranteed operating limit.

Build evidence
batch by batch.

01

Repeatability

Can the manufacturing workflow produce controlled, characterized material consistently?

02

Application fit

How does the material perform in the models and formulations customers actually use?

03

Production readiness

What documentation, process controls and applicable approvals are required for supply?

CONTINUE EXPLORINGExplore the applications↗